GB
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
TECHNICAL DATA
DIMENSIONS
Height 900 - 915 mm
Widht 1000 mm
Depth 600 mm (excluding door handles)
GENERAL
Gas connection Rp ½ (½" BSP female)
Pressure test point Hotplate burner injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection 230-240V~ 50Hz.
Total electrical heat input 6.00-6.80 kW
INSTALLATION INSTRUCTIONS
230-240V~
Cat II2H3+
G20 at 20 mbar
Cat II2H3+
G30 at 28 - 30 mbar
G31 at 37 mbar
BURNER
HEAT INPUT HEAT INPUT INJECTOR HEAT INPUT GAS RATE INJECTOR BY-PASS
HOTPLATE
Front Left
1.90 kW 102 Z 2.00 kW 138 g/hr 65 35
HOTPLATE
Rear Left
3.00 kW 116 Y 3.00 kW 218 g/hr 86 44
HOTPLATE
Wok Outer
Centre Front
4.10 kW 110 x 2 4.10 kW 298 g/hr 70 x 2 57
HOTPLATE
Wok Inner
Centre Front
1.00 kW 74 0.90 kW 73 g/hr 44 24
HOTPLATE
Auxiliary
Centre Rear
1.00 kW 71 X 1.00 kW 73 g/hr 50 24
HOTPLATE
Front Right
1.50 kW 88 X 1.50 kW 110 g/hr 60 35
HOTPLATE
Rear Right
1.50 kW 88 X 1.50 kW 110 g/hr 60 35
TWIN GRILL 2.50 kW
L/H OVEN 1.60 kW
R/H OVEN 1.80 kW
WARMING
DRAWER
0.15 kW