Hotpoint CH60DTXF S Instruções de Utilização Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 7
8
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
INSTALLATION INSTRUCTIONS
TECHNICAL DATA
Gas connection Rp ½ (½" BSP female)
Pressure test point Front left hotplate injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection 4mm
2
twin and earth
230/240V a.c. 50Hz.
CH60DTXF S S CH60DTCF S





HEAT INPUT INJECTOR HEAT INPUT INJECTOR
HOTPLATE
Front Left
4.1 kW 100+72+100 3.8 kW (275g/h) 63+42+63
HOTPLATE
Rear Right
3.05 kW 116 3.0 kW (220g/h) 86
HOTPLATE
Front Right and Rear Left
2.0 kW 103 2.0 kW (145g/h) 70
TOTAL LOAD 4.5 / 4.9 kW
!"




HEAT INPUT INJECTOR HEAT INPUT INJECTOR
HOTPLATE
Front Left and Rear Right
3.05 kW 116 3.0 kW (220g/h) 86
HOTPLATE
Front Right and Rear Left
2.0 kW 103 2.0 kW (145g/h) 70
TOTAL LOAD 4.5 / 4.9 kW
CH60DPCF S CH60DPXF S
Vista de página 7